The reminder most owners forget
Irrigation systems are common on properties around Aubrey, and almost every one of them has a backflow assembly somewhere near where the sprinkler line leaves the house supply. Most owners never think about it after the system goes in. Then the city asks for the annual test, and the first question I usually hear is what a backflow assembly is and why anyone needs to test it.
It is a fair question. The assembly is easy to ignore, it sits there doing nothing visible, and the sprinklers run the same whether it works or not. That is exactly why the test exists. A failed backflow assembly gives no sign at the sprinkler heads. The only way to know it still protects your drinking water is to put gauges on it and check.
How the reminder arrives depends on who supplies your water, and I will not guess at the details for your address. If you are not sure whether your system has ever been tested, that is reason enough to have it done.
What the assembly is protecting
Your house water is under pressure, and normally it only flows one direction: out of the main, through the meter, into the house and out to the sprinklers. Backflow is water going the other way. It happens when pressure on the supply side drops, say during a water main break or when a fire hydrant is opened hard, and the line briefly pulls water backward. Without protection, whatever is in the sprinkler line can be pulled back toward the drinking water.
And sprinkler lines carry things you would not drink. Water sits in them between cycles, the heads lie in soil and mulch, and fertilizer, pesticide and whatever the dog left on the lawn can all end up near an opening. The backflow assembly is a set of check valves, plus a relief valve on some types, that only lets water move toward the sprinklers. If pressure reverses, the valves close and hold.
What happens during the test
The test itself is short and not much to watch. A licensed tester shuts the sprinklers off, closes the assembly’s shutoff valves in order, and connects a test kit to the small test cocks on the body of the assembly. The gauge reads the pressure across each check valve and, on assemblies that have one, the point where the relief valve opens. Each reading is compared against what that type of assembly is supposed to hold.
Water to the sprinklers is off while the test runs, and the house usually keeps its water the whole time, since the assembly sits on the irrigation branch. You do not need to be home for most of it, as long as the assembly can be reached and the gate or yard is open. When it passes, the results go on the city’s form and get sent in. When it does not, you hear about it right there, with the reason.
The result is filed with your water provider by a licensed tester, so keep a copy of each year’s report. Ask whether the tester is licensed. One who is will answer without hesitating. The test only counts if the right person signs it.
Why assemblies fail, and what a failed test means
Most failures come down to the parts that move. Check valves have rubber seats and springs, and over time the rubber hardens, debris from the line lodges against a seat, or a spring weakens. Hard water does its usual work here too, leaving scale on the moving parts. A relief valve can stick or start to dribble. None of that is unusual on an assembly that has been out in the weather for a while, and none of it means the whole thing has to go.
A failed test usually means a repair. The assembly gets taken apart, the check seats and springs get cleaned or replaced with a repair kit for that model, and it gets tested again. When the body is cracked, badly corroded or the model is too old to get parts for, replacing the assembly is the honest answer. Either way, the retest is what clears it, and the passing numbers are what the city needs to see.
Keeping an above-ground assembly from freezing
Many residential assemblies sit above ground, which makes them easy to test and easy to freeze. A hard February night can split the brass body or crack the bonnet, and the first sign is often water spraying when the sprinklers come back on in spring. The fix for a frozen assembly is usually a new one, so protecting it is worth a little effort in the fall.
The usual approach is to close the irrigation shutoff inside or at the house, open the test cocks a quarter turn so the assembly can drain, and wrap it with an insulated cover made for backflow assemblies. Leave the ball valves on the assembly at a half-open angle so water is not trapped inside them. If your system has a winterization procedure from whoever installed it, follow that. And when you turn the water back on in spring, do it slowly, closing the test cocks first.
If the assembly already froze and is leaking, shut the irrigation supply off and leave it shut. Do not try to tape or clamp a cracked body. It needs replacing, and a replaced assembly needs its own test before the sprinklers go back into service.
Hose bibbs, hydrants and stock tanks
Sprinklers are the big one, but they are not the only cross-connection on a property. A garden hose left lying in a bucket of fertilizer, a pond or a pool can siphon back the same way. That is why outdoor hose bibbs should carry a vacuum breaker, either built into a frost-free bibb or as a small screw-on fitting. It is a small part that does the same job at the tap.
On acreage around Aubrey, yard hydrants and stock tanks raise the same question. A hose or float valve sitting below the water line in a stock tank is a direct path from livestock water back into the supply. An air gap, where the fill pipe ends well above the water, or the right backflow device on that line, closes it. Whether a particular setup needs a testable assembly is something I will tell you when I see it.
Rentals and properties that change hands
Rental and investment owners get caught by this often. The tenant does not know the assembly exists, the previous owner may never have tested it, and the reminder can go to an address nobody checks. If you own a rental with irrigation, put the test on the same calendar as the rest of the maintenance. A failed or missed test is a lot easier to deal with on your schedule than on the city’s.
Buying a house with a sprinkler system is a good moment to find the assembly, see what type it is and get it tested, so you start with a clean record. Same for a newer house in one of the new subdivisions here where the builder put the irrigation in. The assembly went in with the system, and the first test after that is on you.
Getting it done
The backflow testing page for Aubrey covers how the work runs here, and backflow testing has the wider version, including repairs and replacements. When you call (940) 231-5706, have the type of assembly or a phone photo of it handy if you can, and say whether the city has already asked. That tells me how soon it needs doing.
Owners sometimes ask whether they can skip the test if the sprinklers seem fine. They seem fine either way, which is the whole point. A tester with gauges is the only one who can say the valves still hold, and hearing it in your own yard beats finding out some other way.

Speak to the owner
If the city has asked for your test, call me and we will get it on the calendar.